Search    Home | Register | Login | Join | Trade | Forum | Cart


  < Back

     Perlong Medical Equipment Co.,Ltd. 

     About this company : Perlong Medical Equipment Co., Ltd., registered and stationed in Nanjing China, is a subsidiary business of Perlong Group specializing in the import and export of medical equipment. Perlong Group, headquartered in Beijing, have been producing and selling medical equipment in domestic market for more than 30 years,is considered the largest medical equipment manufacturer and supplier in China. These years experience made us very professional. We become export these years.Our products are highly appraised abroad.All factories within the group are awarded with ISO9000 Certificates and will be awarded with CE certificates in 2006. Our main products as follows: Urine chemistry Analyzer Electrolyte Analyzer Microplate Readers/ Washer Biochemistry Analyzer Blood Coagulation Analyzer Multi-functional Anesthesia Unit Patient Monitor Ventilator Hemoglobin Meter X-ray Machine ESR Analyzer etc. More information please see our listings. Should any products be of interest to you, please fell free to login to contact me.

     Contact : Phineas Du 
     Headquarters : No.28-1 Dajiaochang Road, Qinhuai, Nanjing, Jiangsu, 210007, China
     Phone : 86-25-52635350, Fax : 86-25-52635356 
     Website : Log on to trade instantly , Email : Log on to trade instantly

     PUN-2048B Two-channel Blood Coagulation Analyzer PUN-2048B Two-channel Blood Coagulation Analyzer PUN-2048B

Specifications: Number of Channels : 2,37℃±0.2℃ Reagent Storage : 4 Sample Preparation Positions : 6, 3 with timer Reagent Volume : 100μl Stray : ≤1% Interchannel Error : ≤3% Linearity Error : ≤1%
  > Add to cart


     DNM-9602 Microplate Reader DNM-9602 Microplate Reader DNM-9602

Specifications: Measurement System : 8-Channel optical system Measurement Range : 0.001—3.500Abs Photometric Accuracy : ±1% or ±0.001Abs Repeatability : <±0.5% Stability : <0.005Abs Linearity : < ±1% Reading Speed : <5secs/96holes(single wavelength) <7secs/96holes(double wavelength) Filters : Standard: 7 filter(405,450,492,630 nm) or other wavelength on request.
  > Add to cart


     DNM-9602A Microplate Reader  DNM-9602A Microplate Reader DNM-9602A

Specifications: Measurement System : 2-Channel optical system Measurement Range : 0.001—3.500Abs Photometric Accuracy : ±1% or ±0.001Abs Repeatability : <±0.5% Stability : <0.005Abs Linearity : <±1% Reading Speed : <5secs/96holes(single wavelength) <7secs/96holes(double wavelength) Filters : Standard: 450,492nm
  > Add to cart


     DNM-9602G Microplate Reader DNM-9602G Microplate Reader DNM-9602G

Specifications: Measurement System : 8-Channel optical system Measurement Range : 0.000-4.000Abs Photometric Accuracy : ±1% or ±0.001Abs Repeatability : <±0.3% Stability : <0.002Abs Linearity : <±0.5% Reading Speed : <5secs/96holes(single wavelength) <7secs/96holes(double wavelength) Filters : Standard: 7 filters (405, 450, 492,630 nm) or other wavelength on request
  > Add to cart


     DNX-9620 Computerized Microplate Washer DNX-9620 Computerized Microplate Washer DNX-9620

Specifications: Washing Head : 8 or 12 channels Applicable Microplate : 96 , 48 or 32 wells microplate Washing Times Option : 1~9,can be preset Washing Rows Option : 1~12, can be preset Soak Time : 1~3600s Residual Volume : <3μl/well
  > Add to cart


     JINLING-01C Multifunctional Anesthesia Unit JINLING-01C Multifunctional Anesthesia Unit JINLING-01C

Specifications: Suitable for : Adult, pediatrics   Driving Method : Gas driven electrically controlled Ventilation modes : IPPV; SIPPV; SIMV; PEEP Tidal Volume : 50~1200mL Max Insp. Flow : 18L Respiratory Rate : 8~40/m I:E : 1:0.5, 1:1, 1:1.5, 1:2.0, 1:2.5, 1:3.0 Max pressure : ≤6kPa PEEP : 0.1~1.2kPa Sigh Volume : not less than 1.5 times of Tidal Volume Upper airway pressure limit : 1.0kPa~5.4kPa Lower airway pressure limit : ≥0.5kPa Continuous work after mains interruption O2 Supply Speed : 35L/min~75L/min
  > Add to cart


     JINLING-01Multifunctional Anesthesia Unit JINLING-01Multifunctional Anesthesia Unit JINLING-01

Specifications: Flowmeter Range : O2 : 0.1~10L/min   N2O : 0.1~10L/min Oxygen Supply Speed : 35~75L/min Ventilator : Tidal Volume : 50~1200mL/p Respiratory Rate : 6~80/m I/E Ratio : 1:0.5~1:3.0 Airway Pressure Indication : 0~10kPa Airway Pressure Range : 0~10kPa
  > Add to cart


     JINLING-1B Multifunctional Anesthesia Unit JINLING-1B Multifunctional Anesthesia Unit JINLING-1B

Specifications: Flowmeter Range : O2: 0.1~10L/min   N2O: 0.1~10L/min Oxygen Supply Speed : 35~75L/min Ventilator : Humidity Volume : 100~1200mL/p Airway Pressure Indication : -1~7.0kpa(±5%) Airway Pressure Range : 1~7kPa Respiratory Rate : 8~40/m I:E Ratio : 1:1.0~1:3.0
  > Add to cart


     NDY-2B Anesthesia Unit NDY-2B Anesthesia Unit NDY-2B

Specifications: Decompressor range : 0.35mpa~0.40mpa Flowmeter Range : O2: 0.1~10L/min N2O: 0.1~10L/min O2-N2O interlock
  > Add to cart


     PA-500 Ventilator  PA-500 Ventilator PA-500

Specifications: Tidal Volume Adjustment : 50~1400ml Ventilation Capacity per Minute : ≥18L Oxygen Concentration : <45% Ventilator Conformance : ≤30mL/kpa Respiratory Rate : 6~60/m I/E Ratio : 1:1.5,1:2.0,1:2.5,1:3.0 Maximum Safe Pressure : ≤6.0kPa ( Ptr)Range : -0.4~1.0kPa Transfer Time from Controlled to Assistant Respiration : 6s Air Flow Adjustment : 1~12times /m Positive Pressure Adjusting Range at the end of Ventilation : 0.1~1.0kPa Sigh Volume : 150% of humidity volume Oxygen Consumption : ≤1.5Mpa change in pressure after 1-hour operation of oxygen cylinder of 12250kPa/40L.
  > Add to cart


     PA-500A Ventilator PA-500A Ventilator PA-500A

Specifications: Ventilation Mode : IPPV, SIPPV, IMV, SIMV, PCV Frequency : 1~99bpm SIMV Frequency : 1~12bpm I: E : 4: 1, 3: 1, 2: 1, 1: 1, 1: 1.5, 1: 2.0, 1: 2.5, 1: 3.0, 1: 4 Inspratory Plateau : 0~1S Pressure Limit : 1~6kPa Tidal Volume Adjusting Coefficient : 80%~120% Tidal Volume Upper Limit : 0~2000mL Tidal Volume Lower Limit : 0~2000mL Airway Pressure Upper Limit : 1~6kPa Airway Pressure Lower Limit : 0~5kPa Sigh : Each sigh after every 80 times ventilation, 150% of tidal volume. Inspiration Ptr : -0.4kPa~1.0kPa PEEP : 0.1kPa~1.0kPa Silence : ≤120S Display Method : 10.4"color TFT big screen Setup Method : Shuttle knob Optional Battery : >30min Manual ventilation after the failure of AC/DC ventilation O2 Concentration Adjusting Range : 35%~90% Monitoring Parameter: Tidal Volume : 0~9990mL Airway Pressure : 0~10kPa Ventilation Volume : 0~99.9L Ventilation Volume : 0~99L Total Frequency : 0~99bpm Spontaneous Inspratory Frequency : 0~99bpm Identifier for power : AC/DC Airway Impedance Lung Conformance Pressure --- Time waveform Flow Volume --- Time waveform
  > Add to cart


     PUS-2018 Biochemistry Analyzer(with External Pinter) PUS-2018 Biochemistry Analyzer(with External Pinter) PUS-2018

Specifications: Wavelength Range : 340nm~700nm Measurement Range : 0.001~3.000Abs Precision : ±0.001Abs Repeatability : ≤0.005Abs Linearity : ≤±1% Cross-contamination : ≤1% Temperature Accuracy : ±0.1℃ Test Temperature : 25℃、30℃、37℃ Test Method : end-point, kinetic, two-point , standard curve and simple/double wavelength exam. Colorimetric Pool : Titanium alloy Reagent : 400μl~800μl Match all kinds of reagent Sample volume : 20~50μl Display : Photometric absorbance, density, active unit, and normal parameters
  > Add to cart


     PUS-2018 Biochemistry Analyzer(with Internal Pinter) PUS-2018 Biochemistry Analyzer(with Internal Pinter) PUS-2018

Specifications: Wavelength Range : 340nm~700nm Measurement Range : 0.001~3.000Abs Precision : ±0.001Abs Repeatability : ≤0.005Abs Linearity : ≤±1% Cross-contamination : ≤1% Temperature Accuracy : ±0.1℃ Test Temperature : 25℃、30℃、37℃ Test Method : end-point, kinetic, two-point , standard curve and simple/double wavelength exam. Colorimetric Pool : Titanium alloy Reagent : 400μl~800μl Match all kinds of reagent Sample volume : 20~50μl Display : Photometric absorbance, density, active unit, and normal parameters
  > Add to cart


Page 1 of 1
  ^ Back to top

   Bookmark and Share



About Us | Register | Login | Join | Trade | Forum | Cart |  Join  |  Connect  |  Follow
Know-How | Trading Precaution | Phishing Alerts | SOAOnDemand! | VAR 360 | RSS Feed 

  Copyright © 2024 MarginUp All Rights Reserved.
MarginUp User Agreement and Privacy Policy.